Data provided by Italian Ministry of Environment say that in 5 years you consume, just for heating of an apartment, an amount of energy equal to that required for the all construction of the same apartment. The years come down to three if one includes other energy consumption. In terms of primary energy, the building-plant system is responsible for about 45 % of the national energy demand. The rolling-shutter box system, in most cases, is the first responsible for thermal dispersions and input of free heat coming from outside. In addition, the window frames have the obligation of the CE marking to be sold on the free European market. Among the basic requirements, the thermal transmittance is the parameter responsible for the energy performance. The research concerned the energy study of different window frames and rolling-shutter boxes through the use of finite element methodology and experiments in situ. This study was carried out on six different types of windows frames (PVC, wood, and wood-aluminium) and four different models of rolling shutters-boxes (all with structure made by expanded polystyrene). The experimental analysis allowed the comparison between the thermal transmittance values calculated according to the UNI EN ISO 10077-1/2 and measured in accordance with ISO 9869.
Numerical and experimental thermal analysis for the improvement of various types of windows frames and rolling-shutter boxes
CARDINALE, Nicola;ROSPI, GIANLUCA;CARDINALE, TIZIANA
2015-01-01
Abstract
Data provided by Italian Ministry of Environment say that in 5 years you consume, just for heating of an apartment, an amount of energy equal to that required for the all construction of the same apartment. The years come down to three if one includes other energy consumption. In terms of primary energy, the building-plant system is responsible for about 45 % of the national energy demand. The rolling-shutter box system, in most cases, is the first responsible for thermal dispersions and input of free heat coming from outside. In addition, the window frames have the obligation of the CE marking to be sold on the free European market. Among the basic requirements, the thermal transmittance is the parameter responsible for the energy performance. The research concerned the energy study of different window frames and rolling-shutter boxes through the use of finite element methodology and experiments in situ. This study was carried out on six different types of windows frames (PVC, wood, and wood-aluminium) and four different models of rolling shutters-boxes (all with structure made by expanded polystyrene). The experimental analysis allowed the comparison between the thermal transmittance values calculated according to the UNI EN ISO 10077-1/2 and measured in accordance with ISO 9869.File | Dimensione | Formato | |
---|---|---|---|
Art-Int J Energy Environ Eng-Marzo2015.pdf
accesso aperto
Descrizione: Articolo principale
Tipologia:
Pdf editoriale
Licenza:
Dominio pubblico
Dimensione
2.98 MB
Formato
Adobe PDF
|
2.98 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.