Cyclic voltammetry was used to investigate the electrochemical behaviour of a nafion/ruthenium(III) modified glassy carbon towards the electrooxidation of hydrazine compounds in perchloric acid solutions. Flow injection experiments were performed to characterize the electrode as an amperometric sensor for the determination of hydrazine compounds. The effects of several common interferents on the amperometric signal were measured. The electrode response was stable: over 30 h only a 6% signal loss was observed. The 3 sigma limit of detection (LOD) was 1x10(-7) M, corresponding to 0.65 ng of injected hydrazine sulfate (i.e. 3.2 mu g l(-1) hydrazine). The detector response was linearly dependent on the concentrations of hydrazine compounds over three orders of magnitude above the LOD. Examples of the determination of hydrazine added to drinking water and river water are reported. Good levels of recovery (95-101%) were obtained at the 1-13 mu M level.

CATALYTIC OXIDATION AND FLOW DETECTION OF HYDRAZINE COMPOUNDS AT A NAFION/RUTHENIUM (III) CHEMICALLY MODIFIED ELECTRODE.

CASELLA, Innocenzo Giuseppe;SALVI, Anna Maria;
1997-01-01

Abstract

Cyclic voltammetry was used to investigate the electrochemical behaviour of a nafion/ruthenium(III) modified glassy carbon towards the electrooxidation of hydrazine compounds in perchloric acid solutions. Flow injection experiments were performed to characterize the electrode as an amperometric sensor for the determination of hydrazine compounds. The effects of several common interferents on the amperometric signal were measured. The electrode response was stable: over 30 h only a 6% signal loss was observed. The 3 sigma limit of detection (LOD) was 1x10(-7) M, corresponding to 0.65 ng of injected hydrazine sulfate (i.e. 3.2 mu g l(-1) hydrazine). The detector response was linearly dependent on the concentrations of hydrazine compounds over three orders of magnitude above the LOD. Examples of the determination of hydrazine added to drinking water and river water are reported. Good levels of recovery (95-101%) were obtained at the 1-13 mu M level.
1997
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/6506
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 63
  • ???jsp.display-item.citation.isi??? 60
social impact