Several neural diseases appear related to the neurotransmitter acethylcholine (ACh) and its metabolite choline (Ch) brain levels so that their simultaneous determination is essential. A cross-talk and interference free dual electrode amperometric biosensor for the simultaneous determination of both analytes has been developed. Acetylcholinesterase (AChE) and choline oxidase (ChO) were immobilized by glutaraldehyde co-crosslinking with bovine serum albumin. A very efficient rejection of electroactive interferents has been achieved by a novel electrosynthesized polymeric bilayer membrane composed by overoxidised poly(pyrrole) and poly(2-naphthol) films. Sensitivities towards several electroactive interferents ranged from ca. 0.04% (e.g. ascorbate) to ca. 0.3% (e.g. dopamine) of those relevant to ACh and Ch (11 and 15microA/microM, respectively). Detection limits (at S/N = 3) in flow injection analysis were ca. 100nM for both ACh and Ch at the ChO–AChE electrode and ca. 40nM for Ch at the ChO sensor. Biosensor performances appear more than adequate for brain tissue homogenates and cerebrospinal fluids analysis where average levels in the low micromolar range are typically found.

Electrosynthesized poly(pyrrole)/poly(2-naphthol) bilayer membrane as an effective anti-interference layer for simultaneous determination of acetylcholine and choline by a dual electrode amperometric biosensor

GUERRIERI, Antonio;
2006-01-01

Abstract

Several neural diseases appear related to the neurotransmitter acethylcholine (ACh) and its metabolite choline (Ch) brain levels so that their simultaneous determination is essential. A cross-talk and interference free dual electrode amperometric biosensor for the simultaneous determination of both analytes has been developed. Acetylcholinesterase (AChE) and choline oxidase (ChO) were immobilized by glutaraldehyde co-crosslinking with bovine serum albumin. A very efficient rejection of electroactive interferents has been achieved by a novel electrosynthesized polymeric bilayer membrane composed by overoxidised poly(pyrrole) and poly(2-naphthol) films. Sensitivities towards several electroactive interferents ranged from ca. 0.04% (e.g. ascorbate) to ca. 0.3% (e.g. dopamine) of those relevant to ACh and Ch (11 and 15microA/microM, respectively). Detection limits (at S/N = 3) in flow injection analysis were ca. 100nM for both ACh and Ch at the ChO–AChE electrode and ca. 40nM for Ch at the ChO sensor. Biosensor performances appear more than adequate for brain tissue homogenates and cerebrospinal fluids analysis where average levels in the low micromolar range are typically found.
2006
File in questo prodotto:
File Dimensione Formato  
Elecrosynthesized.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: DRM non definito
Dimensione 288.16 kB
Formato Adobe PDF
288.16 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/6201
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 69
  • ???jsp.display-item.citation.isi??? 66
social impact