The objective of this work is to demonstrate the potential of using passive microwave data to monitor flood and discharge conditions and to infer watershed hydraulic and hydrologic parameters. The case study is the major flood in Iowa in summer 2008. A new Polarisation Ratio Variation Index (PRVI) was developed based on a multi-temporal analysis of 37 GHz satellite imagery from the Advanced Microwave Scanning Radiometer (AMSR-E) to calculate and detect anomalies in soil moisture and/or inundated areas. The Robust Satellite Technique (RST) which is a change detection approach based on the analysis of historical satellite records was adopted. A rating curve has been developed to assess the relationship between PRVI values and discharge observations downstream. A time-lag term has been introduced and adjusted to account for the changing delay between PRVI and streamflow. Moreover, the Kalman filter has been used to update the rating curve parameters in near real time. The temporal variability of the b exponent in the rating curve formula shows that it converges toward a constant value. A consistent 21-day time lag, very close to an estimate of the time of concentration, was obtained. The agreement between observed discharge downstream and estimated discharge with and without parameters adjustment was 65 and 95%, respectively. This demonstrates the interesting role that passive microwave can play in monitoring flooding and wetness conditions and estimating key hydrologic parameters.

A multi-temporal analysis of AMSR-E data for flood and discharge monitoring during the 2008 flood in Iowa

TRAMUTOLI, Valerio;
2011-01-01

Abstract

The objective of this work is to demonstrate the potential of using passive microwave data to monitor flood and discharge conditions and to infer watershed hydraulic and hydrologic parameters. The case study is the major flood in Iowa in summer 2008. A new Polarisation Ratio Variation Index (PRVI) was developed based on a multi-temporal analysis of 37 GHz satellite imagery from the Advanced Microwave Scanning Radiometer (AMSR-E) to calculate and detect anomalies in soil moisture and/or inundated areas. The Robust Satellite Technique (RST) which is a change detection approach based on the analysis of historical satellite records was adopted. A rating curve has been developed to assess the relationship between PRVI values and discharge observations downstream. A time-lag term has been introduced and adjusted to account for the changing delay between PRVI and streamflow. Moreover, the Kalman filter has been used to update the rating curve parameters in near real time. The temporal variability of the b exponent in the rating curve formula shows that it converges toward a constant value. A consistent 21-day time lag, very close to an estimate of the time of concentration, was obtained. The agreement between observed discharge downstream and estimated discharge with and without parameters adjustment was 65 and 95%, respectively. This demonstrates the interesting role that passive microwave can play in monitoring flooding and wetness conditions and estimating key hydrologic parameters.
2011
File in questo prodotto:
File Dimensione Formato  
Temimi et al., 2011.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: DRM non definito
Dimensione 2.66 MB
Formato Adobe PDF
2.66 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/35826
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 32
social impact