The CMS Barrel resistive plate chambers quality tests are performed at three different sites (Bari, Pavia and Sofia), where equivalent software and hardware tools are used. Data from the first 210 detectors are available for a comprehensive analysis. The paper describes the general experimental set-up, the test procedure and the cosmic muon test results. The muon trajectory reconstruction algorithm, used for precise studies, is presented. The criteria to accept or reject a detector are also given. The CMS final-design chambers show an average efficiency greater than 95%. r 2005 Elsevier B.V. All rights reserved.
Cosmic ray tests of double-gap resistive plate chambers for the CMS experiment
CAVALLO, Nicola;COMUNALE, Giuliana;
2005-01-01
Abstract
The CMS Barrel resistive plate chambers quality tests are performed at three different sites (Bari, Pavia and Sofia), where equivalent software and hardware tools are used. Data from the first 210 detectors are available for a comprehensive analysis. The paper describes the general experimental set-up, the test procedure and the cosmic muon test results. The muon trajectory reconstruction algorithm, used for precise studies, is presented. The criteria to accept or reject a detector are also given. The CMS final-design chambers show an average efficiency greater than 95%. r 2005 Elsevier B.V. All rights reserved.File in questo prodotto:
File | Dimensione | Formato | |
---|---|---|---|
nima_550_2005_116.pdf
accesso aperto
Tipologia:
Documento in Post-print
Licenza:
DRM non definito
Dimensione
439.96 kB
Formato
Adobe PDF
|
439.96 kB | Adobe PDF | Visualizza/Apri |