On 18 March 2025, a moderate earthquake with moment magnitude Mw 4.2 struck the Basilicata region in Southern Italy. The event occurred at 09:01:25 UTC with an epicentre located approximately 4 km northeast of the city of Potenza (PZ). The earthquake was clearly felt across the urban area and followed by a sequence of low-magnitude aftershocks. A few hours after the main shock, researchers from the University of Basilicata installed a temporary structural monitoring network to check the structural conditions of several buildings located in Potenza. This installation enabled the acquisition of accelerometric recordings of several aftershocks, providing a valuable dataset for preliminary observations on structural seismic response. The monitoring campaign focused on two adjacent twin buildings with similar geometry and structural layout but different seismic design strategies: one conventionally fixed at the base and the other equipped with seismic base isolation made by rubber bearings. Comparative analyses revealed distinct differences in dynamic response. The results highlight the need for refined regulatory tools to address near-epicentral conditions, particularly potential dynamic interactions among the vertical ground-motion component, the vertical vibration frequencies of the superstructure, and floor-system resonance. While not critical for ultimate limit states, these effects may influence comfort and performance in operational and damage limit states.

Vertical Ground-Motion Effects in Base-Isolated Buildings: Preliminary Observations from Twin Fixed-Base and Base-Isolated Structures During the 18 March 2025 Potenza Sequence

Rocco Ditommaso
;
Felice Carlo Ponzo
2026-01-01

Abstract

On 18 March 2025, a moderate earthquake with moment magnitude Mw 4.2 struck the Basilicata region in Southern Italy. The event occurred at 09:01:25 UTC with an epicentre located approximately 4 km northeast of the city of Potenza (PZ). The earthquake was clearly felt across the urban area and followed by a sequence of low-magnitude aftershocks. A few hours after the main shock, researchers from the University of Basilicata installed a temporary structural monitoring network to check the structural conditions of several buildings located in Potenza. This installation enabled the acquisition of accelerometric recordings of several aftershocks, providing a valuable dataset for preliminary observations on structural seismic response. The monitoring campaign focused on two adjacent twin buildings with similar geometry and structural layout but different seismic design strategies: one conventionally fixed at the base and the other equipped with seismic base isolation made by rubber bearings. Comparative analyses revealed distinct differences in dynamic response. The results highlight the need for refined regulatory tools to address near-epicentral conditions, particularly potential dynamic interactions among the vertical ground-motion component, the vertical vibration frequencies of the superstructure, and floor-system resonance. While not critical for ultimate limit states, these effects may influence comfort and performance in operational and damage limit states.
2026
File in questo prodotto:
File Dimensione Formato  
BUILDINGS_2026_Ditommaso.pdf

solo utenti autorizzati

Licenza: Non definito
Dimensione 3.85 MB
Formato Adobe PDF
3.85 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/208536
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact