Objective: We tested the ability of optical coherence tomography (OCT) to identify very early stages of atherosclerosis in vivo. Methods: Twelve New Zealand white male rabbits (weight 3.5-4.0 kg) underwent perivascular electrical injury of the common carotid arteries, and were then fed a cholesterol-rich diet. At 43 ± 16 (range 27-63) days after injury, arteries were imaged by OCT, then rabbits were euthanized and vessels processed for histology. Results: A total of 14 carotid arteries were imaged by OCT and histology; 22 atherosclerotic lesions were identified, 16 (73%) occurring at the site of the electrical injury. At histology, 4 lesions were defined as Stary type I (isolated macrophages), 8 as type II (intracellular lipid accumulations), and 10 as type III (small extracellular lipid pools). No advanced (≥type IV) lesions were documented. OCT failed to detect any type I lesions, but correctly defined a minority (2/8, 25%) of type II lesions and the majority (8/10, 80%) of type III lesions. For type III lesions, sensitivity, specificity and diagnostic accuracy of OCT were 80%, 95%, and 95%, respectively. Conclusions: OCT can accurately detect intermediate (type-III) atherosclerotic lesions in vivo, but still fails to identify earlier stages of atherosclerosis. © 2006 Elsevier Ireland Ltd. All rights reserved.

Optical coherence tomography accurately identifies intermediate atherosclerotic lesions-An in vivo evaluation in the rabbit carotid artery

Stabile E.;Filippini A.;
2007-01-01

Abstract

Objective: We tested the ability of optical coherence tomography (OCT) to identify very early stages of atherosclerosis in vivo. Methods: Twelve New Zealand white male rabbits (weight 3.5-4.0 kg) underwent perivascular electrical injury of the common carotid arteries, and were then fed a cholesterol-rich diet. At 43 ± 16 (range 27-63) days after injury, arteries were imaged by OCT, then rabbits were euthanized and vessels processed for histology. Results: A total of 14 carotid arteries were imaged by OCT and histology; 22 atherosclerotic lesions were identified, 16 (73%) occurring at the site of the electrical injury. At histology, 4 lesions were defined as Stary type I (isolated macrophages), 8 as type II (intracellular lipid accumulations), and 10 as type III (small extracellular lipid pools). No advanced (≥type IV) lesions were documented. OCT failed to detect any type I lesions, but correctly defined a minority (2/8, 25%) of type II lesions and the majority (8/10, 80%) of type III lesions. For type III lesions, sensitivity, specificity and diagnostic accuracy of OCT were 80%, 95%, and 95%, respectively. Conclusions: OCT can accurately detect intermediate (type-III) atherosclerotic lesions in vivo, but still fails to identify earlier stages of atherosclerosis. © 2006 Elsevier Ireland Ltd. All rights reserved.
2007
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/205783
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 44
  • ???jsp.display-item.citation.isi??? ND
social impact