Objectives The aim of this meta-analysis was to evaluate and compare the efficacy of the 2 different neuroprotection systems in preventing embolization during carotid artery stenting (CAS), as detected by diffusion-weighted magnetic resonance imaging (DW-MRI).Background Data from randomized and nonrandomized studies comparing both types of embolic protection devices revealed contrasting evidence about their efficacy in neuroprotection, as assessed by the incidence of new ischemic lesions detected by DW-MRI.Methods Eight studies, enrolling 357 patients, were included in the meta-analysis. Our study analyzed the incidence of new ischemic lesions/patient, comparing filter cerebral protection and proximal balloon occlusion.Results Following CAS, the incidence of new ischemic lesions/patient detected by DW-MRI was significantly lower in the proximal balloon occlusion group (effect size [ES]: -0.43; 95% confidence interval [CI]: -0.84 to -0.02, I2 = 70.08, Q = 23.40). Furthermore, following CAS, the incidence of lesions at the contralateral site was significantly lower in the proximal protection group (ES: -0.50; 95% CI: -0.72 to -0.27, I2 = 0.00, Q = 3.80).Conclusions Our meta-analysis supports the concept that the use of proximal balloon occlusion compared with filter cerebral protection is associated with a reduction of the amount of CAS-related brain embolization. The data should be confirmed by a randomized clinical trial.

Cerebral embolic lesions detected with diffusion-weighted magnetic resonance imaging following carotid artery stenting: A meta-analysis of 8 studies comparing filter cerebral protection and proximal balloon occlusion

Stabile E.;Sannino A.;
2014-01-01

Abstract

Objectives The aim of this meta-analysis was to evaluate and compare the efficacy of the 2 different neuroprotection systems in preventing embolization during carotid artery stenting (CAS), as detected by diffusion-weighted magnetic resonance imaging (DW-MRI).Background Data from randomized and nonrandomized studies comparing both types of embolic protection devices revealed contrasting evidence about their efficacy in neuroprotection, as assessed by the incidence of new ischemic lesions detected by DW-MRI.Methods Eight studies, enrolling 357 patients, were included in the meta-analysis. Our study analyzed the incidence of new ischemic lesions/patient, comparing filter cerebral protection and proximal balloon occlusion.Results Following CAS, the incidence of new ischemic lesions/patient detected by DW-MRI was significantly lower in the proximal balloon occlusion group (effect size [ES]: -0.43; 95% confidence interval [CI]: -0.84 to -0.02, I2 = 70.08, Q = 23.40). Furthermore, following CAS, the incidence of lesions at the contralateral site was significantly lower in the proximal protection group (ES: -0.50; 95% CI: -0.72 to -0.27, I2 = 0.00, Q = 3.80).Conclusions Our meta-analysis supports the concept that the use of proximal balloon occlusion compared with filter cerebral protection is associated with a reduction of the amount of CAS-related brain embolization. The data should be confirmed by a randomized clinical trial.
2014
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/205757
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 86
  • ???jsp.display-item.citation.isi??? ND
social impact