The installation of the new GE1/1 station of Gas Electron Multiplier (GEM) detectors in the Compact Muon Solenoid (CMS) experiment was completed during the Long Shutdown 2 (LS2) phase of the Large Hadron Collider (LHC). The GE1/1 station has been operational in the CMS detector since the beginning of the Run-3 data-taking phase, and for the first time the GEM technology was deployed on a large scale, comprised of 144 chambers and tested in running conditions as integral part of the CMS data acquisition, reconstruction, and analysis chain. The deployment of the GEM detector required careful planning throughout the years, posing several challenges of practical and conceptual nature in integrating an entirely new subsystem in the existing CMS frame. Operations on the other hand provided a unique opportunity to test the GEM technology in never-before seen conditions, and an occasion to study their behavior during data taking. In describing some of the solutions to the posed challenges and the findings during the data-taking, the article will focus on the aspects related to power system management, including high-voltage and current monitoring, which is intrinsically related to the response of the chamber due to the workings of the GEM foil charge flow. To this end, this article will illustrate the operations of GE1/1 detectors in the first two years of Run-3, with a particular focus on the analysis of discharge occurrences, on the generation of short circuits in GE1/1 GEM foils and on the adopted mitigation strategies. The applied layout of the GEM detectors is thoroughly described, and detailed operating conditions of the detectors are discussed, along with the actions taken to mitigate these events.
Study on discharge and short circuit generation in CMS GE1/1 triple-GEM detectors during Run 3
The installation of the new GE1/1 station of Gas Electron Multiplier (GEM) detectors in the Compact Muon Solenoid (CMS) experiment was completed during the Long Shutdown 2 (LS2) phase of the Large Hadron Collider (LHC). The GE1/1 station has been operational in the CMS detector since the beginning of the Run-3 data-taking phase, and for the first time the GEM technology was deployed on a large scale, comprised of 144 chambers and tested in running conditions as integral part of the CMS data acquisition, reconstruction, and analysis chain. The deployment of the GEM detector required careful planning throughout the years, posing several challenges of practical and conceptual nature in integrating an entirely new subsystem in the existing CMS frame. Operations on the other hand provided a unique opportunity to test the GEM technology in never-before seen conditions, and an occasion to study their behavior during data taking. In describing some of the solutions to the posed challenges and the findings during the data-taking, the article will focus on the aspects related to power system management, including high-voltage and current monitoring, which is intrinsically related to the response of the chamber due to the workings of the GEM foil charge flow. To this end, this article will illustrate the operations of GE1/1 detectors in the first two years of Run-3, with a particular focus on the analysis of discharge occurrences, on the generation of short circuits in GE1/1 GEM foils and on the adopted mitigation strategies. The applied layout of the GEM detectors is thoroughly described, and detailed operating conditions of the detectors are discussed, along with the actions taken to mitigate these events.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/201637
Citazioni
ND
0
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.