Objectives: This study sought to evaluate 1-year safety and efficacy of dual-layered mesh-covered carotid stent systems (DLS) for carotid artery stenting (CAS). Background: Small clinical studies evaluating 1-year outcomes of CAS performed with 2 available DLS, Roadsaver (RS) (Terumo Corp., Tokyo, Japan) and CGuard (CG) (InspireMD, Boston, Massachusetts), have been published. Methods: The authors performed an individual patient-level meta-analysis including studies enrolling more than 100 CAS with DLS. The primary endpoint was the death and stroke rate; secondary endpoints were restenosis and in-stent thrombosis rates at 1 year. Results: Patients were divided into 2 groups according to DLS (RS n = 250; CG n = 306). At 1 year, 11 patients died (1.97%), 7 patients in the group RS (2.8%) and 4 patients in the CG one (1.31%); and 10 strokes occurred, 4 in the group RS (1.6%) and 6 in the CG one (1.96%). Overall death and stroke rate was 3.77% (n = 21), 11 events in the group RS group (4.4%) and 10 in the CG group (3.27%). Symptomatic status was the only predictor of death and or stroke. At 1 year, restenosis occurred in 12 patients (2.1%), 10 in the group RS (4%) and 2 in the CG one (0.65%) (p = 0.007). In-stent thrombosis occurred in 1 patient (0.18%) in the CG group (0.32%). RS use was the only independent predictor of restenosis. Conclusions: This study suggests that DLS use for CAS is associated with a low 1-year death and stroke rate, and the specific DLS stent used could affect the restenosis rate.

Use of Dual-Layered Stents for Carotid Artery Angioplasty: 1-Year Results of a Patient-Based Meta-Analysis

Stabile, Eugenio;Esposito, Giovanni
2020-01-01

Abstract

Objectives: This study sought to evaluate 1-year safety and efficacy of dual-layered mesh-covered carotid stent systems (DLS) for carotid artery stenting (CAS). Background: Small clinical studies evaluating 1-year outcomes of CAS performed with 2 available DLS, Roadsaver (RS) (Terumo Corp., Tokyo, Japan) and CGuard (CG) (InspireMD, Boston, Massachusetts), have been published. Methods: The authors performed an individual patient-level meta-analysis including studies enrolling more than 100 CAS with DLS. The primary endpoint was the death and stroke rate; secondary endpoints were restenosis and in-stent thrombosis rates at 1 year. Results: Patients were divided into 2 groups according to DLS (RS n = 250; CG n = 306). At 1 year, 11 patients died (1.97%), 7 patients in the group RS (2.8%) and 4 patients in the CG one (1.31%); and 10 strokes occurred, 4 in the group RS (1.6%) and 6 in the CG one (1.96%). Overall death and stroke rate was 3.77% (n = 21), 11 events in the group RS group (4.4%) and 10 in the CG group (3.27%). Symptomatic status was the only predictor of death and or stroke. At 1 year, restenosis occurred in 12 patients (2.1%), 10 in the group RS (4%) and 2 in the CG one (0.65%) (p = 0.007). In-stent thrombosis occurred in 1 patient (0.18%) in the CG group (0.32%). RS use was the only independent predictor of restenosis. Conclusions: This study suggests that DLS use for CAS is associated with a low 1-year death and stroke rate, and the specific DLS stent used could affect the restenosis rate.
2020
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/190108
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 35
  • ???jsp.display-item.citation.isi??? ND
social impact