Objectives: Patent hemostasis (PH) is essential for preventing radial artery occlusion (RAO) after trans-radial procedures; however, it remains unclear how it should be obtained. The aim of this multicenter randomized study was to evaluate whether the use of an adjustable device (AD), inflated with a pre-determined amount of air (AoA), was more effective than a non-adjustable device (non-AD) for achieving PH, thereby reducing the incidence of RAO. Methods: We enrolled a total of 480 patients undergoing transradial procedure at 3 Italian institutions. Before the procedure, a modified Reverse Barbeau Test (mRBT) was performed in all patients to evaluate the AoA to be eventually inflated in the AD. After the procedure, patients were randomized into 2 groups: (1) AD Group, using TR-Band (Terumo) inflated with the pre-determined AoA; and 2) non-AD Group, using RadiStop (Abbott). An RBT was performed during compression to demonstrate the achievement of PH, as well as 24 hours later to evaluate the occurrence of RAO. Results: PH was more often obtained in the AD Group compared with the non-AD Group (90% vs 64%, respectively, P less than .001), with no difference in terms of bleedings. RAO occurred more often in the non-AD Group compared with the AD Group (10% vs 3%, respectively, P less than .001). Of note, mRBT was effective at guiding AD inflation and identifying high-risk patients in whom PH was more difficult to obtain. Conclusions: The use of AD, filled with a predetermined AoA, allowed PH significantly more often compared with non-AD, providing a significantly reduced incidence of RAO.

A comparison between radial artery compression devices for patent hemostasis after transradial percutaneous interventions

Stabile, Eugenio;Esposito, Giovanni
2024-01-01

Abstract

Objectives: Patent hemostasis (PH) is essential for preventing radial artery occlusion (RAO) after trans-radial procedures; however, it remains unclear how it should be obtained. The aim of this multicenter randomized study was to evaluate whether the use of an adjustable device (AD), inflated with a pre-determined amount of air (AoA), was more effective than a non-adjustable device (non-AD) for achieving PH, thereby reducing the incidence of RAO. Methods: We enrolled a total of 480 patients undergoing transradial procedure at 3 Italian institutions. Before the procedure, a modified Reverse Barbeau Test (mRBT) was performed in all patients to evaluate the AoA to be eventually inflated in the AD. After the procedure, patients were randomized into 2 groups: (1) AD Group, using TR-Band (Terumo) inflated with the pre-determined AoA; and 2) non-AD Group, using RadiStop (Abbott). An RBT was performed during compression to demonstrate the achievement of PH, as well as 24 hours later to evaluate the occurrence of RAO. Results: PH was more often obtained in the AD Group compared with the non-AD Group (90% vs 64%, respectively, P less than .001), with no difference in terms of bleedings. RAO occurred more often in the non-AD Group compared with the AD Group (10% vs 3%, respectively, P less than .001). Of note, mRBT was effective at guiding AD inflation and identifying high-risk patients in whom PH was more difficult to obtain. Conclusions: The use of AD, filled with a predetermined AoA, allowed PH significantly more often compared with non-AD, providing a significantly reduced incidence of RAO.
2024
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/190061
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact