This paper aims to show some results of seismic assessment of Romanian Orthodox existing masonry churches, by extending the multi-level approach proposed by the Italian directive for seismic risk evaluation of cultural heritage. To this scope, a sample of six existing churches is examined, belonging to a church typology characterized by a single vaulted nave and a bell tower incorporated into the main façade. All churches considered in this study are located in the Banat region, which is an area with a medium–high seismic hazard. Firstly, territorial Level of Valuations (LV0 and LV1) are conducted on the churches sample examined. Afterwards, local (LV2) and global (LV3) valuations are performed on a case study, the ˆ Invierea Domnului church, assumed representative of all the churches sample under consideration. In particular, local analyses are performed on some church architectural portions with the kinematic limit analysis. Whereas, global analyses are conducted with non-linear push-over approach. Comments and comparisons of the obtained results are reported for each LV examined.

Seismic assessment of Romanian Orthodox masonry churches in the Banat area through a multi-level analysis framework

Lo Monaco A.
;
D'Amato M.;
2023-01-01

Abstract

This paper aims to show some results of seismic assessment of Romanian Orthodox existing masonry churches, by extending the multi-level approach proposed by the Italian directive for seismic risk evaluation of cultural heritage. To this scope, a sample of six existing churches is examined, belonging to a church typology characterized by a single vaulted nave and a bell tower incorporated into the main façade. All churches considered in this study are located in the Banat region, which is an area with a medium–high seismic hazard. Firstly, territorial Level of Valuations (LV0 and LV1) are conducted on the churches sample examined. Afterwards, local (LV2) and global (LV3) valuations are performed on a case study, the ˆ Invierea Domnului church, assumed representative of all the churches sample under consideration. In particular, local analyses are performed on some church architectural portions with the kinematic limit analysis. Whereas, global analyses are conducted with non-linear push-over approach. Comments and comparisons of the obtained results are reported for each LV examined.
2023
File in questo prodotto:
File Dimensione Formato  
2023_Seismic assessment of Romanian Orthodox masonry churches in the Banat area through a multi-level analysis framework_compressed.pdf

solo utenti autorizzati

Tipologia: Pdf editoriale
Licenza: Versione editoriale
Dimensione 1.53 MB
Formato Adobe PDF
1.53 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/174635
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 14
social impact