Few studies have investigated so far the collapse capacity of buildings with base-isolation. In such studies, preliminary considerations have been drawn based on a number of assumptions regarding: (i) the methodology used for assessing the collapse capacity, (ii) the collapse conditions and failure modes assumed for both superstructure and isolation system, and (iii) the numerical modeling assumptions. The main results pointed out that the collapse conditions of base-isolated buildings may occur for intensity levels slightly higher than those associated with the design earthquake. In this paper, further developments are made through the use of enhanced models for the description of the behavior of a rubber-based isolation system and the assumption of more rational collapse conditions. Collapse fragility functions, in terms of mean and dispersion values, are proposed for two archetypes representative of existing buildings retrofitted using the seismic isolation technique. The collapse margin ratio (median collapse capacity Sa, C, namely the spectral acceleration associated to a probability of exceedance equal to 50%, divided by the design spectral acceleration at the collapse prevention limit state) has been evaluated for each examined case-study. Values ranging from 1.10 to 1.45 were found.
Evaluating collapse fragility curves for existing buildings retrofitted using seismic isolation
Flora A.
;Perrone G.;Cardone D.
2020-01-01
Abstract
Few studies have investigated so far the collapse capacity of buildings with base-isolation. In such studies, preliminary considerations have been drawn based on a number of assumptions regarding: (i) the methodology used for assessing the collapse capacity, (ii) the collapse conditions and failure modes assumed for both superstructure and isolation system, and (iii) the numerical modeling assumptions. The main results pointed out that the collapse conditions of base-isolated buildings may occur for intensity levels slightly higher than those associated with the design earthquake. In this paper, further developments are made through the use of enhanced models for the description of the behavior of a rubber-based isolation system and the assumption of more rational collapse conditions. Collapse fragility functions, in terms of mean and dispersion values, are proposed for two archetypes representative of existing buildings retrofitted using the seismic isolation technique. The collapse margin ratio (median collapse capacity Sa, C, namely the spectral acceleration associated to a probability of exceedance equal to 50%, divided by the design spectral acceleration at the collapse prevention limit state) has been evaluated for each examined case-study. Values ranging from 1.10 to 1.45 were found.File | Dimensione | Formato | |
---|---|---|---|
Evaluating_collapse_fragility_curves_for_existing.pdf
accesso aperto
Tipologia:
Documento in Post-print
Licenza:
DRM non definito
Dimensione
1.91 MB
Formato
Adobe PDF
|
1.91 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.