This paper focuses on a preliminary structural analysis of the current concept design of DEMO vacuum vessel (VV). The VV structure is checked against a vertical load due to a Vertical Displacement Event in combination with the weight force of all components that the main vessel shall bear. Different configurations for the supports are considered. Results show that the greatest safety margins are reached when the tokamak is supported through the lower ports rather than the equatorial ports, though all analyzed configurations are compliant with RCC-MRx design rules.
Preliminary structural assessment of DEMO vacuum vessel against a vertical displacement event
Mozzillo R.
;
2016-01-01
Abstract
This paper focuses on a preliminary structural analysis of the current concept design of DEMO vacuum vessel (VV). The VV structure is checked against a vertical load due to a Vertical Displacement Event in combination with the weight force of all components that the main vessel shall bear. Different configurations for the supports are considered. Results show that the greatest safety margins are reached when the tokamak is supported through the lower ports rather than the equatorial ports, though all analyzed configurations are compliant with RCC-MRx design rules.File in questo prodotto:
Non ci sono file associati a questo prodotto.