This paper presents a diagnostic system, gamma-ray alpha-particle monitor (GRAM), for continuous monitoring of deuterium-tritium fusion α-particles in the MeV energy range escaped from the plasma to the first wall. The diagnostic is based on the detection of γ-rays produced in nuclear reactions. The reactions 9Be(α,nγ)12C and 10B(α,pγ)13C have been selected. For that purpose, Be- or 10B-target is placed on the first wall, where the alphas are expected to be mostly lost. Striking the target, the lost alphas generate specific γ-rays, if their energy E α > 1.5 MeV. To measure this γ-ray emission, the target should be in the field of view of a collimated detector, which is protected from neutrons and background gammas. The calibrated detector could deliver absolute values of the lost α-particle flux with a temporal resolution depending on intensity of losses. A high-performance γ-ray spectrometer with a novel architecture, GRITER, is proposed to be used in GRAM. It consists of a stack of the optically isolated high-Z fast scintillators with independent signal readout. GRITER is supposed to be operated at count-rates substantially exceeding the capability of a single crystal detector of the same size. The GRAM diagnostic system consists of two identical spectrometers, which measure both γ-rays due to α-particle loss and γ-ray background ensuring reliable data in a harsh reactor environment. GRAM could be tested during the non-DT plasma operation monitoring lost DD fusion products, neutral beam heating D-ions (E D > 0.5 MeV) and ICRF accelerated H- and 3He-ions through the detection of γ-rays resulting from nuclear reactions. The use of GRAM on JET and ITER, including events with extremely high loss rates, is discussed.

Escaping alpha-particle monitor for burning plasmas

R. Fresa;
2018-01-01

Abstract

This paper presents a diagnostic system, gamma-ray alpha-particle monitor (GRAM), for continuous monitoring of deuterium-tritium fusion α-particles in the MeV energy range escaped from the plasma to the first wall. The diagnostic is based on the detection of γ-rays produced in nuclear reactions. The reactions 9Be(α,nγ)12C and 10B(α,pγ)13C have been selected. For that purpose, Be- or 10B-target is placed on the first wall, where the alphas are expected to be mostly lost. Striking the target, the lost alphas generate specific γ-rays, if their energy E α > 1.5 MeV. To measure this γ-ray emission, the target should be in the field of view of a collimated detector, which is protected from neutrons and background gammas. The calibrated detector could deliver absolute values of the lost α-particle flux with a temporal resolution depending on intensity of losses. A high-performance γ-ray spectrometer with a novel architecture, GRITER, is proposed to be used in GRAM. It consists of a stack of the optically isolated high-Z fast scintillators with independent signal readout. GRITER is supposed to be operated at count-rates substantially exceeding the capability of a single crystal detector of the same size. The GRAM diagnostic system consists of two identical spectrometers, which measure both γ-rays due to α-particle loss and γ-ray background ensuring reliable data in a harsh reactor environment. GRAM could be tested during the non-DT plasma operation monitoring lost DD fusion products, neutral beam heating D-ions (E D > 0.5 MeV) and ICRF accelerated H- and 3He-ions through the detection of γ-rays resulting from nuclear reactions. The use of GRAM on JET and ITER, including events with extremely high loss rates, is discussed.
2018
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/134645
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 4
social impact