The aim of the present work is the development of a predictive mathematical model for the analysis and optimization of energy systems used to control the environment microclimate in industrial plants. This model provides not only the evaluation of the optimal configuration on the basis of different process parameters in the existing environments, but also the analysis and the prediction of the energy consumption of a plant during the design phase. The model describes the thermodynamics of conditioning processes and allows the evaluation of the influence of design variables and of hourly averaged weather conditions on energy consumption. The model is developed both in TRNSYS-17 and C ++ programming language such that it can also be used under MATLAB computing environment. The results obtained with the two models are compared under different climatic conditions in terms of heating/cooling and humidification/dehumidification energy consumption, thus assessing the accuracy of both models. The results obtained by using different set-point conditions under different climatic zones are also presented.

Numerical Simulation of Energy Systems to Control Environment Microclimate

GENCO, ANGELA;VIGGIANO, ANNARITA;MAGI, Vinicio
2016-01-01

Abstract

The aim of the present work is the development of a predictive mathematical model for the analysis and optimization of energy systems used to control the environment microclimate in industrial plants. This model provides not only the evaluation of the optimal configuration on the basis of different process parameters in the existing environments, but also the analysis and the prediction of the energy consumption of a plant during the design phase. The model describes the thermodynamics of conditioning processes and allows the evaluation of the influence of design variables and of hourly averaged weather conditions on energy consumption. The model is developed both in TRNSYS-17 and C ++ programming language such that it can also be used under MATLAB computing environment. The results obtained with the two models are compared under different climatic conditions in terms of heating/cooling and humidification/dehumidification energy consumption, thus assessing the accuracy of both models. The results obtained by using different set-point conditions under different climatic zones are also presented.
2016
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/123072
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 6
social impact