In this study an experimental study on a biological methane oxidation column presented with the aim to calibrate a mathematical model developed in an earlier study. The column was designed to reproduce at lab-scale a real biofilter trying to consider the more probable landfill boundary conditions. Although the methane oxidation efficiency in the column was lower than the expected (around 35%), an appropriate model implementation showed an acceptable agreement between the outcomes data of the model simulation and the experimental data (with Theil's Inequality Coefficient value of 0.08). A calibrated model allows a better management of the biofilter performance in terms of methane oxidation.
Methane oxidation in a biofilter (Part 2): A lab-scale experiment for model calibration
AMODEO, CORRADO;MASI, Salvatore;ZIRPOLI, PIERFRANCESCO;MANCINI, Ignazio Marcello;CANIANI, Donatella
2015-01-01
Abstract
In this study an experimental study on a biological methane oxidation column presented with the aim to calibrate a mathematical model developed in an earlier study. The column was designed to reproduce at lab-scale a real biofilter trying to consider the more probable landfill boundary conditions. Although the methane oxidation efficiency in the column was lower than the expected (around 35%), an appropriate model implementation showed an acceptable agreement between the outcomes data of the model simulation and the experimental data (with Theil's Inequality Coefficient value of 0.08). A calibrated model allows a better management of the biofilter performance in terms of methane oxidation.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.