The paper proposes the results of an experimental study on bituminous binders aimed to define master curves of rutting factor. The experimentation was performed in agreement with the SHRP Protocol specifications on an original bituminous binder and the corresponding modified binders obtained with the addition by weight of 3, 4 and 5% of radial SBS. The laboratory tests were carried out with a rotational rheometer (DSR) at the temperatures of 50, 60, 70, 80, 90 and 100°C working on bituminous binders before and after long term ageing executed with the PAV device. The Rutting Factor used as indicator able to describe the permanent deformation phenomenon (PD) of asphalt concrete for flexible road pavements is the subject of recent studies that place doubt on its effectiveness in favor of other parameters such as, for example, the ZSV (Zero Shear Viscosity). However, these studies have not yet furnished definitive and universally shared results so the Rutting Factor is always used in the practice and also in research. The master curves implementation allows to evaluate, in the medium-high range of temperatures, the response of the binder in terms of |G*|/sin d highlighting the optimum range of use to contain PD.
Master curves of rutting factor for bituminous binders
AGOSTINACCHIO, Michele;CIAMPA, DONATO;DIOMEDI, Maurizio;OLITA, Saverio
2011-01-01
Abstract
The paper proposes the results of an experimental study on bituminous binders aimed to define master curves of rutting factor. The experimentation was performed in agreement with the SHRP Protocol specifications on an original bituminous binder and the corresponding modified binders obtained with the addition by weight of 3, 4 and 5% of radial SBS. The laboratory tests were carried out with a rotational rheometer (DSR) at the temperatures of 50, 60, 70, 80, 90 and 100°C working on bituminous binders before and after long term ageing executed with the PAV device. The Rutting Factor used as indicator able to describe the permanent deformation phenomenon (PD) of asphalt concrete for flexible road pavements is the subject of recent studies that place doubt on its effectiveness in favor of other parameters such as, for example, the ZSV (Zero Shear Viscosity). However, these studies have not yet furnished definitive and universally shared results so the Rutting Factor is always used in the practice and also in research. The master curves implementation allows to evaluate, in the medium-high range of temperatures, the response of the binder in terms of |G*|/sin d highlighting the optimum range of use to contain PD.File | Dimensione | Formato | |
---|---|---|---|
5th ICONFBMP 1 2011.pdf
solo utenti autorizzati
Tipologia:
Pdf editoriale
Licenza:
DRM non definito
Dimensione
566.89 kB
Formato
Adobe PDF
|
566.89 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.