Earthquakes in the recent past continue to provide more and more information on the seismic behavior of existing buildings and on the related economic losses. For the reason it is interesting to compare the damage of buildings stocks archived after earthquakes survey activities. In this paper a study of the damage occurred on masonry buildings after L’Aquila 2009 and Emilia 2012 earthquakes is carried out, by considering the data available in the web-gis Da.D.O platform. Firstly, fragility curves are illustrated and compared by considering the vulnerability classes of Da.D.O. (Class A, Class B and Class C1). Then, an approach is proposed in order to evaluate the total Expected Annual Loss (EALtot) and its contributions due to the several damage level (D1, …, D5). The preliminary obtained results show that, with reference to the two masonry buildings stocks considered, the higher contribution to the (EALtot) is given by the damage level D3, that may be considered as the life safety limit state. In the case analyzed, the corresponding EALD3 results almost equal to 1/3 of EALtot.

Seismic risk analysis on masonry buildings damaged by L'Aquila 2009 and Emilia 2012 earthquakes

D'Amato M.;
2022-01-01

Abstract

Earthquakes in the recent past continue to provide more and more information on the seismic behavior of existing buildings and on the related economic losses. For the reason it is interesting to compare the damage of buildings stocks archived after earthquakes survey activities. In this paper a study of the damage occurred on masonry buildings after L’Aquila 2009 and Emilia 2012 earthquakes is carried out, by considering the data available in the web-gis Da.D.O platform. Firstly, fragility curves are illustrated and compared by considering the vulnerability classes of Da.D.O. (Class A, Class B and Class C1). Then, an approach is proposed in order to evaluate the total Expected Annual Loss (EALtot) and its contributions due to the several damage level (D1, …, D5). The preliminary obtained results show that, with reference to the two masonry buildings stocks considered, the higher contribution to the (EALtot) is given by the damage level D3, that may be considered as the life safety limit state. In the case analyzed, the corresponding EALD3 results almost equal to 1/3 of EALtot.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S245232162300135X-main.pdf

solo utenti autorizzati

Tipologia: Pdf editoriale
Licenza: Versione editoriale
Dimensione 1.32 MB
Formato Adobe PDF
1.32 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/174715
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 3
social impact