This paper reports the preliminary results obtained from a campaign of experimental measurements carried out on two strategic structures located in Central Italy and affected by the seismic sequence started on August 24, 2016. The epicentre was located among the municipalities of Accumoli (province of Rieti), Ama-trice (province of Rieti) and Arquata del Tronto (province of Ascoli Piceno). About 51 seismic events have been recorded from August 24, 2016 to February 03, 2017. The dynamic characterization of a hospital in Spoleto and of a school in Norcia retrofitted with dissipative bracing devices, were carried out to detect the stiffness variation, assumed as damage indicator, during the seismic sequence. Data was provided by the Seismic Observatory of Structures (OSS), a network of permanent seismic monitoring systems installed on public buildings, bridges and dams and managed by the Italian Department of Civil Protection (DPC). Modal parameters have been identified from the accelerometric responses recorded at several floors of the buildings.

Preliminary analysis of the dynamic behavior of two strategic buildings subjected to the 2016 central italy earthquake

Iacovino C.;Ditommaso R.;Ponzo F. C.
2019-01-01

Abstract

This paper reports the preliminary results obtained from a campaign of experimental measurements carried out on two strategic structures located in Central Italy and affected by the seismic sequence started on August 24, 2016. The epicentre was located among the municipalities of Accumoli (province of Rieti), Ama-trice (province of Rieti) and Arquata del Tronto (province of Ascoli Piceno). About 51 seismic events have been recorded from August 24, 2016 to February 03, 2017. The dynamic characterization of a hospital in Spoleto and of a school in Norcia retrofitted with dissipative bracing devices, were carried out to detect the stiffness variation, assumed as damage indicator, during the seismic sequence. Data was provided by the Seismic Observatory of Structures (OSS), a network of permanent seismic monitoring systems installed on public buildings, bridges and dams and managed by the Italian Department of Civil Protection (DPC). Modal parameters have been identified from the accelerometric responses recorded at several floors of the buildings.
2019
9780429426506
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/142910
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact