A glucose amperometric biosensor based on glucose oxidase immobilized on an overoxidized polypyrrole (PPyox) platinum modified electrode, by glutaraldehyde co-crosslinking with bovine serum albumine, is described. The advantages of covalent immobilization techniques (e.g. high loading and long term stability of the enzyme) are coupled with the excellent interferent rejection of electrosynthesized non-conducting polymers. The sensor showed an apparent Michaelis-Menten constant of 16 ± 0.8 mM, a maximum current density of 490 microA/cm2 and a shelf lifetime of at least 3 months. Ascorbate, urate, cysteine and acetaminophen at their maximum physiological concentrations produced a glucose bias in the low micromolar range. Flow-injection response was linear up to 20 mM glucose with typical sensitivity of 84·0 ± 1·5 nA/mM. The sensor was tested for glucose determination of untreated serum samples from both normal and diabetic subjects; results of amperometric assay compared well with those obtained by a standard enzymatic-colorimetric method.

Electrosynthesized non-conducting polymers as permselective membranes in amperometric enzyme electrodes: a glucose biosensor based on a co-crosslinked glucose oxidase/overoxidized polypyrrole bilayer

GUERRIERI, Antonio;
1998-01-01

Abstract

A glucose amperometric biosensor based on glucose oxidase immobilized on an overoxidized polypyrrole (PPyox) platinum modified electrode, by glutaraldehyde co-crosslinking with bovine serum albumine, is described. The advantages of covalent immobilization techniques (e.g. high loading and long term stability of the enzyme) are coupled with the excellent interferent rejection of electrosynthesized non-conducting polymers. The sensor showed an apparent Michaelis-Menten constant of 16 ± 0.8 mM, a maximum current density of 490 microA/cm2 and a shelf lifetime of at least 3 months. Ascorbate, urate, cysteine and acetaminophen at their maximum physiological concentrations produced a glucose bias in the low micromolar range. Flow-injection response was linear up to 20 mM glucose with typical sensitivity of 84·0 ± 1·5 nA/mM. The sensor was tested for glucose determination of untreated serum samples from both normal and diabetic subjects; results of amperometric assay compared well with those obtained by a standard enzymatic-colorimetric method.
1998
File in questo prodotto:
File Dimensione Formato  
Electrosynthesized non-conducting polymers as permselective membranes .pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: DRM non definito
Dimensione 802.3 kB
Formato Adobe PDF
802.3 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/4517
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 86
  • ???jsp.display-item.citation.isi??? 86
social impact