Gold microparticles dispersed on glassy carbon structures mere characterized by SEM, Some aspects of the electrooxidation mechanism of carbohydrates in alkaline medium were investigated by cyclic voltammetry. The chemically modified electrode described was tested in flow injection and anion-exchange LC with pulsed amperometric detection. The electrode response was stable: over 8 h a 1.53% signal loss was observed for all of the investigated carbohydrates. Typical relative standard deviations ranged between 0.9 and 3.5%. The detector response was linearly dependent on the concentrations of polyhydroxyl compounds and monosaccharides over three orders of magnitude, Linear plots of 1/I-p and 1/c indicated a Langmuir-type adsorption of analyte on the catalytic sites, All investigated carbohydrates were detected at the picomole level. The determination of glucose in human biological fluids was achieved by LC in an alkaline medium.

COLLOIDAL GOLD SUPPORTED ONTO GLASSY CARBON SUBSTRATES AS AN AMPEROMETRIC SENSOR FOR CARBOHYDRATES IN FLOW INJECTION AND LIQUID CHROMATOGRAPHY.

CASELLA, Innocenzo Giuseppe;
1996-01-01

Abstract

Gold microparticles dispersed on glassy carbon structures mere characterized by SEM, Some aspects of the electrooxidation mechanism of carbohydrates in alkaline medium were investigated by cyclic voltammetry. The chemically modified electrode described was tested in flow injection and anion-exchange LC with pulsed amperometric detection. The electrode response was stable: over 8 h a 1.53% signal loss was observed for all of the investigated carbohydrates. Typical relative standard deviations ranged between 0.9 and 3.5%. The detector response was linearly dependent on the concentrations of polyhydroxyl compounds and monosaccharides over three orders of magnitude, Linear plots of 1/I-p and 1/c indicated a Langmuir-type adsorption of analyte on the catalytic sites, All investigated carbohydrates were detected at the picomole level. The determination of glucose in human biological fluids was achieved by LC in an alkaline medium.
1996
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11563/2538
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 39
social impact